Kirjaudu sisään, jotta voit käyttää lisätoimintoja tuotetunnistusta varten.
Luottoraja ylitetty
Tilaukset pidossa
Tällä suodatuksella ei löytynyt mitään tietoja!
KNORR-BREM
K144925N49 K144925N49 ABS-anturi

Tekniset tiedot:
Plug type: Hirschmann
Cable angle: 90 deg.
Cable protection: Without
Temperature Range Coil & Head Zone [°C]:
-40…+200°C; +210°C max.1h
Temperature Range Cable Zone [°C]:
-40…+160°C; +220°C max.1h
Temperature Range Cable Ass. incl. Plug [°C]:
-40…+80°C; +120°C max.1h
Supplied with grease and clamping sleeve: No
KNORR-BREM
K144939N49 K144939N49 ABS-anturi

Tekniset tiedot:
Ingress Protection Rating: IPX9K
Body Type: 90°
Connector Type:
Metri-Pack 280 Series 2-Way Sealed Connector (Male)
Harness Length: 1092
Convoluted Tubing Included: No
Clamping Sleeve Included: No
Grommet Included: Yes
Grease Included: No
Minimum Operating Temperature: -40 °F (-40 °C)
KNORR-BREM
K144940N49 K144940N49 ABS-anturi

Tekniset tiedot:
Ingress Protection Rating: IPX9K
Body Type: 90°
Connector Type:
Metri-Pack 280 Series 2-Way Sealed Connector (Female)
Harness Length: 1185
Convoluted Tubing Included: No
Clamping Sleeve Included: No
Grommet Included: Yes
Grease Included: No
Minimum Operating Temperature: -50 °F (-45 °C)
KNORR-BREM
K144941N49 K144941N49 ABS-anturi

Tekniset tiedot:
Ingress Protection Rating: IPX9K
Body Type: 90°
Connector Type:
Metri-Pack 280 Series 2-Way Sealed Connector (Male)
Harness Length: 820
Convoluted Tubing Included: No
Clamping Sleeve Included: No
Grommet Included: Yes
Grease Included: No
Minimum Operating Temperature: -40 °F (-40 °C)
KNORR-BREM
K1450042E4 K1450042E4 ABS-anturi

Tekniset tiedot:
Plug type: Deutsch
Cable angle: Straight
Cable protection: Without
Temperature Range Coil & Head Zone [°C]:
-40…+160°C; +180°C max.1h
Temperature Range Cable Zone [°C]:
-40…+160°C; +220°C max.1h
Temperature Range Cable Ass. incl. Plug [°C]:
-40…+80°C; +120°C max.1h
Supplied with grease and clamping sleeve: No
KNORR-BREM
K1450052E4 K1450052E4 ABS-anturi

Tekniset tiedot:
Plug type: Deutsch
Cable angle: Straight
Cable protection: Without
Temperature Range Coil & Head Zone [°C]:
-40…+160°C; +180°C max.1h
Temperature Range Cable Zone [°C]:
-40…+160°C; +220°C max.1h
Temperature Range Cable Ass. incl. Plug [°C]:
-40…+80°C; +120°C max.1h
Supplied with grease and clamping sleeve: No
KNORR-BREM
K1450162E4 K1450162E4 ABS-anturi

Tekniset tiedot:
Cable angle: Straight
Cable protection: Without
Temperature Range Coil & Head Zone [°C]:
-40…+160°C; +180°C max.1h
Temperature Range Cable Zone [°C]:
-40…+160°C; +220°C max.1h
Temperature Range Cable Ass. incl. Plug [°C]:
-40…+80°C; +120°C max.1h
Supplied with grease and clamping sleeve: No
1541 alkaen 1581
Viimeksi katsottu