Tällä suodatuksella ei löytynyt mitään tietoja!
I53027
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M22x1,5
Bleed-back safety feature:
Not included
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M22x1,5
Bleed-back safety feature:
Not included
I63733AT
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I63753AT
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I66912AT
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I67992AT
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I68199
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I69421
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: No circuit
Circuit 4 - Open/close pressure [bar]:
No circuit
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: No circuit
Circuit 4 - Open/close pressure [bar]:
No circuit
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I74309
Suojaventtiili, monipiiri
Tekniset tiedot:
Circuit 1 - Open/close pressure [bar]:
7,1 -0,4
Circuit 2 - Open/close pressure [bar]:
7,1 -0,4
Tekniset tiedot:
Circuit 1 - Open/close pressure [bar]:
7,1 -0,4
Circuit 2 - Open/close pressure [bar]:
7,1 -0,4
I80204
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Viimeksi katsottu