I93562
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 11,12,21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
External series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 11,12,21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
External series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I93563
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 11,12,21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,9
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,9
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6,5-0,3 / >4,9
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,5-0,3 / >4,9
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
External series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 11,12,21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,9
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,9
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6,5-0,3 / >4,9
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,5-0,3 / >4,9
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
External series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
I99814
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal parallel supply to all Circuits
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal parallel supply to all Circuits
With Electrical pressure sensing: No
II36008
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0 -0,3 / >7
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0 -0,3 / >7
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5 -0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5 -0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0 -0,3 / >7
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0 -0,3 / >7
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5 -0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5 -0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
II36154
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,8-0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,8-0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6,3-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,3-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 2
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,8-0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,8-0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6,3-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,3-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 2
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
II37463004
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
II38749F0041
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from C's 1 and
2 to 3, C4 is before C1-2
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from C's 1 and
2 to 3, C4 is before C1-2
With Electrical pressure sensing: Yes
K001041004
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
K001041M4
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
K001041M7
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >5,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
K019904N00
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.5+0.3/ >=5,2
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Viimeksi katsottu