K019905N00
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6.6-0.3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K019906N00
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.0-0.3/ >=5,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K019907N00
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.0-0.3/ 5,5-0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K019908N00
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7.0-0.3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K019911N00
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6.5-0.3/ >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K025852N03
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
<=8,0 / >=6,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
<=8,0 / 5,5±0,25
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
<=8,0 / >=6,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
<=8,0 / 5,5±0,25
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K025852N50
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
<=8,0 / >=6,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
<=8,0 / 5,5±0,25
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
>=7,5 / 6,5±0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
<=8,0 / >=6,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
<=8,0 / 5,5±0,25
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
K048309N50
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5, 25, 26: M22x1,5, 28: M12x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=5,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5, 25, 26: M22x1,5, 28: M12x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=5,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
K048309N52
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5, 25, 26: M22x1,5, 28: M12x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=5,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5, 25, 26: M22x1,5, 28: M12x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=5,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
9,0-0,3 / >=7,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
K063136N17
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,25+0,3 / >4,0+0,7
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,25+0,3 / >4,0+0,7
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
K063136N67
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,25+0,3 / >4,0+0,7
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,25+0,3 / >4,0+0,7
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5+0,3 / >5,0
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
K096082N50
Suojaventtiili, monipiiri
Tekniset tiedot:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,6-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: Yes
Tekniset tiedot:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,6-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: Yes